Menu
Your Cart

HySecurity StrongArm DOT 28 UPS - CONTACT US FOR YOUR SUPER LOW PRICE!

HySecurity StrongArm DOT 28 UPS - CONTACT US FOR YOUR SUPER LOW PRICE!
HySecurity StrongArm DOT 28 UPS - CONTACT US FOR YOUR SUPER LOW PRICE!
  • Stock: In Stock
  • Model: StrongArm DOT 28 UPS
  • SKU: HS-SADOT28UPS
Price Too Low to Publish

 

 

 

Made In America
UPS backup, DOT traffic barrier arm, 28 ft, Open/Close: 5s/6s
STRONGARMDOT 28 UPS is a powerful, rugged, high duty cycle, industrial grade, hydraulic barrier arm operator that exceeds all operator reliability, longevity, maintenance and security standards. This ultra-durable barrier arm is specifically designed for Department of Transportation (DOT) and traffic applications where safety, functionality, long-life, and very low maintenance are demanded. StrongArmDOT features a "breakaway arm" that pivots and returns to its centered position after being hit, perfect for reversible traffic lanes, traffic metered highway on-ramps and other controlled roadway applications. Lowest total cost of ownership. The Uninterruptible DC Power Supply provides 300 cycles UPS backup after an AC power loss.*

Open arms up to 28 ft, to a full 90º, in 5 seconds. Rest arm in open or closed position. Center, breakaway yoke for aluminum or aluminum/fiberglass arm options. Few moving parts, all enclosed in secure, strong uni-body 10 gauge welded hot dipped galvanized steel chassis with stainless steel cover for superior anti-corrosion protection. Keyed T-lock option protects all electrical controls and parts from vandalism. Optional arm light kit.

Retain full functionality during an AC power outage using HySecurity’s advanced DC Power Supply with HyCharger DC™, a powerful 50A three stage charger, custom built for continuous duty and long battery life. The DC Power Supply is a separate insulated and ventilated enclosure containing two sealed maintenance free AGM 110Ah, 12VDC batteries. Available in single phase only: Low voltage: 60/50Hz (requires 30A branch circuit) or High voltage: 60/50Hz (requires 15A branch circuit). Be certain to order the correct HyCharger DC™ voltage model as chargers are not field convertible.

Easily configure barrier arm operation to specific site requirements with unique and unequalled Smart Touch Controller. PC interface provided for easy configuration and quick troubleshooting using Smart Touch Analyze and Retrieve Tool (S.T.A.R.T.). Upload latest software, troubleshoot system and save operator configurations. Programmable dual gate or sequenced gate integration. Three configurable user relays plus optional Hy8Relay™ - an extended relay module providing eight additional programmable relay outputs.

Monitor gate system and accessory status, system operational malfunctions, maintenance alerts, or gate breach alarms. Communicate security or operational events to security command and control or service technician in real time via Ethernet/fiber using optional web based HyNet™ Gateway. Target specific security and operational alerts to specific recipients. View or download 16,000 plus events (logged in non-volatile memory) from a remote location or on-site for precise and quick system troubleshooting. Operate and configure gate remotely.
Note: HySecurity’s DC Power Supply enclosure must be mounted within 10 ft (3 m) of the operator with a minimum of 6 gauge wire used to connect between the DC supply and gate operator. For longer distances, call HySecurity Tech Support. Arm mounting bracket and breakaway pivot prices are not included in StrongArmDOT base prices. See “StrongArm Options” for arm configurations/pricing.


Product Info
FeaturesRobust, heavy duty components Yield decades of high cycle, low maintenance operationUp to 28 ft arms (8.5 m) 5 seconds to open; 6 seconds to closePower supply option UPS battery backed up & solar model available
SpecificationsDuty Cycle 2,000 cycles/day*Open/Close Time 5 seconds to open; 6 seconds to closeArm Length Max Up to 28 ft (8.5 m)Arm Design Center yoke mount. Aluminum up to 24 ft (7 m), fiberglass up to 16 ft (5 m), or aluminum-fiberglass 28 ft (8.5 m)Horsepower 3/4 hpDrive HydraulicUninterruptible Power Supply DC Power Supply w/HyCharger DC™ provides up to 300 cycles after an AC power loss.1 Phase Power 115V 60/50Hz, 23A** or 208-230V 60/50Hz, 11.5A3 Phase Power n/aTemperature Rating -40° to 158° F (-40° to 70° C) No heater necessaryCommunication RS-232, RS-485, Ethernet/fiber using optional HyNet™ Gateway accessoryUser Controls Smart Touch Controller with 70+ configurable settings. Smart Touch keypad and 32 character, OLED display or a PC using S.T.A.R.T. software.Relays Three configurable user relays: one 30VDC, 3A solid state and two 250VAC, 10A electromechanical; Optional Hy8Relay™ for 8 additional relay outputsETL Listed (UL325) Usage Class I, II, III, IVEnclosure DC Power Supply: Type 3R, 30w x 30h x 12d inch (76w x 76h x 30.5d cm)Finish Hot dipped galvanized with stainless steel coverWarranty 5 year

Write a review

Note: HTML is not translated!
Bad Good

This website uses cookies to ensure you get the best experience on our website. Privacy Policy