NorthStar NP2 Loop Detector



Price: $129.00

Available Options


Description

NorthStar NP2 Loop Detector

Northstar NP2 has been specifically designed and engineered for use in the Parking/Access Control industries. With standard operations including programmable pulse and presence options, fail-safe or fail-secure operation, compatibility with all radio controls, timing features and more, the NP2 covers your detection needs.

The NP2’s wide inductance range allows for use with small loops sometimes found in the Parking/Access Control industries (for recommended loop sizes please consult the Northstar Loop Information Guide).

Separate indicators for power on, detect relay 1, detect relay 2 and fault provide for quick visual verification of proper operation. Loop diagnostics are easily viewed with the front panel fault indicator, differentiating between current and historical faults thus facilitating troubleshooting.

Small size and full list of features lend the NP2 to any Parking/Access Control use from simple presence detection to configured pulse/presence lengths with output extensions and/or delays.

Reliable operation and long field life are key engineering goals in every Northstar product.

Specification

Features
Features 10 selectable Sensitivities
4 selectable Frequencies
Wrong voltage protection
Output Timing – Extend & Delay
Selectable Presence times
Selectable Pulse lengths
Separate Power, Detect and Fault Indicators
Automatic Sensitivity Boost
1 Year Warranty
Specifications
Specifications Relay Output Rating: 7A 277VAC/30VDC

Power: 240 VAC, 120 VAC or 12-24 VAC/DC
(70mA DC or 1W AC)

Inductance Range: 20uH to 1500uH

Temperature Range: -30 F to +180 F

Lead-In Length: up to 2500 ft. with proper lead-in and loop.

Dimensions: 1 3/8”W X 3 3/32”H X 3 ½”L

Weight: 8 oz

Supply Voltage – incorrect voltage supplied to the unit will
not result in damage, the unit will simply not operate until
correct voltage is supplied. No fuses need to be reset.

Indicators – front panel indicators include:
Power – Green, solid with correct power supplied
Relay 1 – Red, solid during detect
Relay 2 – Red, solid during detect
Fault – Yellow, solid during current fault, flashing for historical fault
Sensitivity Boost – automatic during detect except in the highest sensitivity setting (9).

Factory Options:
Presence lengths of 15, 30, 60 minutes or permanent
Pulse lengths of 250mS, 500mS, 1, 2 or 4 seconds
Extend times of 0, 2, 5 or 10 seconds
Delay times of 0, 1, 2 or 4 seconds
Relay 1 fail-safe or fail-secure
Relay 2 fail-safe or fail-secure

11 Pin Connector:
Pin # Function Color
1 Power (+) Black
2 Power (-) White
3 Relay 2 N.O. Orange
4 Ground Green
5 Relay 1 Com Yellow
6 Relay 1 N.O. Blue
7 Loop Gray
8 Loop Brown
9 Relay 2 Com Red
10 Relay 1 N.C. White/Blk
11 Relay 2 N.C. White/Red