When only the best will do. Tired of replacing 3 and 4 yr old detectors? This is the one that lasts as long as the best openers we sell! Think they are too expensive? Cheapest one you can buy if you never have to replace it.
Northstar NP2 has been specifically designed and engineered for use in the Parking/Access Control industries. With standard operations including programmable pulse and presence options, fail-safe or fail-secure operation, compatibility with all radio controls, timing features and more, the NP2 covers your detection needs.
The NP2’s wide inductance range allows for use with small loops sometimes found in the Parking/Access Control industries (for recommended loop sizes please consult the Northstar Loop Information Guide).
Separate indicators for power on, detect relay 1, detect relay 2 and fault provide for quick visual verification of proper operation. Loop diagnostics are easily viewed with the front panel fault indicator, differentiating between current and historical faults thus facilitating troubleshooting.
Small size and full list of features lend the NP2 to any Parking/Access Control use from simple presence detection to configured pulse/presence lengths with output extensions and/or delays.
Reliable operation and long field life are key engineering goals in every Northstar product.
Product Info | |
Features | 10 selectable Sensitivities 4 selectable Frequencies Wrong voltage protection Output Timing – Extend & Delay Selectable Presence times Selectable Pulse lengths Separate Power, Detect and Fault Indicators Automatic Sensitivity Boost 1 Year Warranty |
Specifications | Output Rating: Solid State both Detect and Fail. 30mA Maximum current sink. Outputs are protected from over-voltage or polarity reversal. Power: 10 to 30 volts AC or DC, 5mA nominal Inductance Range: 20uH to 1500uH Temperature Range: -30 F to +180 F Lead-In Length: up to 2500 ft. with proper lead-in and loop. Dimensions: 2.4” H x 2.25” D x 0.8” W Supply Voltage – incorrect voltage supplied to the unit will not result in damage, the unit will simply not operate until correct voltage is supplied. No fuses need to be reset. Indicators – front panel indicators: Power/Fault – Green, solid with correct power supplied Flashes during a fault condition Fault flash sequence: Single flash and pause = Open Circuit Loop Double flash and pause = Shorted Loop Detect – Red, solid during detect Connector: – 10 position Pin # Function 1 Loop 2 Loop 3 Power – 10 to 30 V AC/DC 4 Not used 5 Not used 6 Fail output 7 Fail output 8 Detect output 9 Power – 10 to 30 V AC/DC 10 Power common |